Recent Projects Category
Recessed Lights, Porch Light Install, Dedicated Microwave circuit
Installed four new recessed lights in vaulted ceiling in living room, replace switch by door for switched receptacle (passed through)
Ran new dedicated 20 amp line from panel to microwave. Microwave was on loaded 15amp circuit causing breaker to trip.
Installed cans in section of kitchen closed off for refrigerator
Tied into existing front porch switch and added additional front porch light, ran circuit to exterior of home and installed pancake box for future light.
Before | After |
Fireplace LCD Mount
Mounted Television above fireplace mantle, ran all wires in wall. Ran new receptacle off existing circuit and hdmi behind television (for TV), also ran new power outlet and hdmi in side cubbyhole (for cable box). While connecting power found switch to be defective and burning up as a result, switch and plate replaced as well.
Before | After |
Bella Pizza 51″ LCD
Tied into existing receptacle circuit and ran power for receptacle behind tv. Plaster with 1/2 gap to fish mc cable through, and concrete block to mount tv to, using 1/2 x 6″ wedge anchors. Stage one of project, second TV to be hung soon.
Before | After |
Bedside LCD installation with networked xbox 360
Installed wall mount for 21″ LCD TV on bedside. Used existing receptacle behind night stand for power. Ran new coaxial cable for tv, and cat 5 for network set up from router to xbox 360.
Before | After |
New light fixture install, closet light install, chandalier replacement
Installed closet light off of existing circuit in opposing wall, fresh install.
Replaced existing chandelier (some assembly required, ok al ot of assembly)
Installed new chandelier in living room where there was no power or attic access, in two story home. Tied into existing switch for switched receptacle.
Before | After |
Before | After |
Replaced Chandelier-assembly required! |
Toilet repair replace flange, flapper, flush valve
Toilet running periodically through the day. Removed tank of toilet and rebuilt internal components replacing flange, flapper, flush valve.
Before | After |
Hot Tub Install
Installed new GFCI breaker for hot tub, ran new circuit from panel box to out side disconnect as seen in picture. Installed pvc in ground and stubbed up with extra whip for company delivering hot tub to hook up.
Kitchen Lights Remodel (pendants, recessed, chandalier), exc.
Removed existing track lighting. Installed four recessed lights in main kitchen area and 2 pendants over bar on first floor in two story home. Also swaped out ceiling fans in living room, and new chandalier in dining room.
Before | After |
Ceiling Fan Replacement
Removal of existing light fixtures, changing existing 3″ box used for lights to 4″ ceiling fan box/bracket.
Before | First Fan | Second Fan |
Generator Control Panel Removal
Removed control panel for large gas generator, disconnected all circuits from generator panel, and rewired to existing panel. Removal of control panel and ouside disconnect only, actual unit removed by another company.
Before | After |